Features:
High efficiency, high reliability and low cost
Switch input voltage range choice
Protection characteristics: short circuit/overload
100% full load and machine test
Air cooling
Working frequency 24 KHz
1 year warranty
Size: 159 * 97 * 38 mm (L * W * H)
Technical parameter:
model |
D-50A |
D-50B |
CH1 |
CH2 |
CH1 |
CH2 |
output |
Dc output voltage |
5V |
12V |
5V |
24V |
Output voltage tolerance |
±2% |
+5,-8% |
±2% |
±8% |
Rated output current |
6A |
2A |
6A |
1A |
Output current range |
1-6A |
0.3-2A |
1-6A |
0.2-1A |
Output power |
54W |
54W |
Ripple and the noise |
50mVp-p |
100mVp-p |
50mVp-p |
100mVp-p |
Dc voltage adjustable scope |
CH1:-5%,+10% |
Start, rise, keep time |
200ms,50ms,20ms Loaded with |
input |
Input voltage range |
85~132 VAC/170~264VAC47~63 Hz;The switch choice |
240~370VDC |
Exchange input current |
1.3A/115VAC0.65A/230VAC |
efficiency |
73% |
73% |
Impulse current |
冷启动电流18A/115V36A/230V |
Leakage current |
<0.5mA/240VAC |
Protection characteristics |
Overload protection |
105%~150% |
Protection way: cut output, intermittent automatic recovery |
environment |
Working temperature, humidity |
-10℃~+60℃;20%~90 %RH |
Keep temperature, humidity |
-20℃~+85℃;10%~95 %RH |
Vibrate resistance |
10~500Hz,2G 10 min. / 1 cycle time, 60 minutes, the axis |
security |
Compression sex |
Input/output: 1.5 KVAC input and between to KVAC output and the earth: 1.5:0.5 KVAC |
Insulation resistance |
Between the input and output, the input and output, and ground: 100 M / 500 VDC Ohms |
Complies with the standards |
Safety standards |
Meet UL1012 |
EMC standard |
Design refer to FCC Part15 J Conduction |
other |
weight |
0.53Kg |
packaging |
24pcs/13.6Kg/0.75CUFT |
note |
1. All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ℃ conditions measuring income value. |
2. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement. |
3. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate. |