Features:
High efficiency, high reliability
For AC power supply input global
100% full load and machine test
Protection characteristics: short circuit/overload/pressure
Has the boot display (light emitting diode (led)
Air cooling
Working frequency 54 KHz
1 year warranty
Size: 159 * 97 * 38 mm (L * W * H)
Technical parameter:
model |
D-60A |
D-60B |
CH1 |
CH2 |
CH1 |
CH2 |
output |
Dc output voltage |
5V |
12V |
5V |
24V |
Output voltage tolerance |
±2% |
±6% |
±2% |
±5% |
Rated output current |
4A |
3A |
3A |
1.8A |
Output current range |
0.3-6A |
0.2-4A |
0.3-6A |
0.2-2.2A |
Output power |
56W |
58W |
Ripple and the noise |
75mVp-p |
150mVp-p |
75mVp-p |
150mVp-p |
Dc voltage adjustable scope |
CH1: -5%,+10% |
CH1: -5%,+10% |
Start, rise, keep time |
300ms,50ms ,80ms/230VAC 800ms,50ms,10ms/115VAC Loaded with |
input |
Input voltage range |
85~264 VAC/ 47~63 Hz; 120~370VDC |
Exchange input current |
2A/115 V 1A/ 230 V |
efficiency |
73% |
76% |
Impulse current |
Cold start current |
30A/115VAC 60A/230VAC |
Leakage current |
<3.5mA/240VAC |
Protection characteristics |
Overload protection |
105%~150% |
Protection way: current limiting, automatic recovery |
Overvoltage protection |
115%~135% |
Protection way: hiccups, auto recovery mode |
environment |
Working temperature, humidity |
-10℃~+60℃;20%~90 %RH |
Keep temperature, humidity |
-20℃~+85℃;10%~95 %RH |
Vibrate resistance |
10 ~ 500 Hz ac, 2 G 10 min. / 1 cycle time, 60 minutes, the axis |
security |
Compression sex |
3: KVAC between input and output input and ground: |
1.5KVAC Output and to |
:0.5KVAC |
Insulation resistance |
Between the input and output, the input and output, and ground: |
100M Ohms/500VDC |
Standards |
Safety standards |
符合UL1012 , UL60950 ,EN60950 |
EMC standard |
Accord with |
EN55022(CLSPR22),EN61000-3-2,-3, EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024 |
other |
weight |
0.54Kg |
packaging |
30pcs/16.7Kg/0.99CUFT |
note |
All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ℃ conditions measuring income value. |
Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement. |
Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate. |
The power to consider as a device installed in final equipment, this equipment must be to make sure it’s EMC index. |
Specific output current see output drop forehead curve. |
|