Features:
For AC power supply input global
Protection characteristics: short circuit/overload/pressure
Air cooling
Can be installed DIN standards guide TS-35/7.5 or 15
Has the boot display (light emitting diode (led)
100% full load and machine test
Working frequency 50 KHz
One year warranty
Size: 55.5 * 125.2 * 100 mm (W * H * D)
Technical parameter:
model |
DR-75-12 |
DR-75-24 |
HDR-75-48 |
output |
Dc output voltage |
12V |
24V |
48V |
Output voltage tolerance |
±2% |
±1% |
±1% |
Rated output current |
6.3A |
3.2A |
1.6A |
Output current range |
0-6.3A |
0-3.2A |
0-1.6A |
Output power |
76W |
76.8W |
76.8W |
Ripple and the noise |
100mVp-p |
150mVp-p |
240mVp-p |
Dc voltage adjustable scope |
17% |
17% |
10% |
Start, rise time |
1000ms,60ms/230VAC Loaded with 1800ms,60ms/115VAC Loaded with |
Keep time |
60ms/230VAC12ms/115VAC Loaded with |
input |
Input voltage range |
85~264 VAC choose 47~63 Hz;120~370VDC |
Exchange input current |
1.6 A/115 V 0.96A/ 230 V |
efficiency |
76% |
80% |
81% |
Impulse current |
Cold start current 20A/115V 40A/230V |
Leakage current |
<1mA/240VAC |
Protection characteristics |
Overload protection |
105%~150% |
Protection way: constant current limiting automatic recovery |
Overvoltage protection |
120%~140% |
Protection way: hiccups, auto recovery mode |
High temperature protection |
TSW1≥85℃±5℃, |
Protection way: cut output, temperature down automatically restored |
environment |
Working temperature, humidity |
-10℃~+60℃;20%~90 %RH |
Keep temperature, humidity |
-20℃~+85℃;10%~95 %RH |
Vibrate resistance |
10 ~ 500 Hz ac, 2 G 10 min. / 1 cycle time, 60 minutes, the axis |
security |
Compression sex |
3: KVAC between input and output and input and output KVAC: 1.5 to 0.5: KVAC |
Insulation resistance |
Between the input and output, the input and output, and ground: 100 M / 500 VDC Ohms |
Complies with the standards |
Safety standards |
符合UL508,TUV EN60950-1 |
EMC standard |
EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2 |
other |
weight |
0.6Kg |
packaging |
20pcs/13Kg/1.1CUFT |
note |
1. All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ℃ conditions measuring income value. |
2. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement. |
3. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate. |
4. The power to consider as a device installed in final equipment, this equipment must be to make sure it’s EMC index. |
Installation dimensions:
|