model |
MS-60-12 |
MS-60-15 |
MS-60-24 |
output |
Dc output voltage |
12V |
15V |
24V |
Output voltage tolerance |
±1% |
±1% |
±1% |
Rated output current |
5A |
4A |
2.5A |
Output current range |
0~5A |
0~4A |
0~2.5A |
Output power |
60W |
60W |
60W |
Ripple and the noise |
100mVp-p |
120mVp-p |
120mVp-p |
Dc voltage adjustable scope |
-9%~+10% |
±10% |
±10% |
Start, rise, keep time |
600ms,30ms,20ms/230VAC |
input |
Input voltage range |
170~264VAC 47~63Hz,235~373VDC |
Exchange input current |
0.8A/230VAC |
efficiency |
82% |
82% |
84% |
Impulse current |
Cold start current 30A/230VAC |
Leakage current |
<1mA/240VAC |
Protection characteristics |
Overload protection |
Protection way: hiccups mode, load abnormal conditions can be removed recovery |
environment |
Working temperature, humidity |
-10℃~+60℃;20%~90%RH(Please refer to reduce the specified number load curve ) |
Keep temperature, humidity |
-20℃~+85℃;10%~95%RH No condensation |
Vibrate resistance |
10~500Hz,2G 10min./ 1 cycle time, 60 minutes, the axis |
security |
Compression sex |
Input/output: 1.5 KVAC input and between to KVAC output and the earth: 1.5:0.5 KVAC |
Insulation resistance |
Between the input and output, the output and input: with ground: 100M Ohms/500VDC |
standards |
Safety standards |
Accord with UL1012 |
EMC standard |
Accord with EN55022,CLASSA |
other |
weight |
0.27kg 111*78*36(L*W*H) |
packaging |
0.27kg/50pcs/14.5kg/0.9CUFT |
note |
1. All the parameters in has not specified, all is in 2 3 0 V voltage input, A C rated load and 2 5 ℃ conditions measuring income value. |
2. Ripple and noise voltage is in 2 0 M H z bandwidth with 1 to 2 inches oscilloscope twisted pair end and 0. 1 mu and 4 7 muon capacitance measurement when. |
3. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate. |