model |
Q-120B |
Q-120C |
Q-120D |
CH1 |
CH2 |
CH3 |
CH4 |
CH1 |
CH2 |
CH3 |
CH4 |
CH1 |
CH2 |
CH3 |
CH4 |
output |
Dc output voltage |
5V |
12V |
-5V |
-12V |
5V |
15V |
-5V |
-15V |
5V |
12V |
24V |
-12V |
Output voltage tolerance (note 3) |
±2% |
±6% |
±6% |
±6% |
±2% |
+10,-5% |
±6% |
+10,-5% |
±2% |
±6% |
±6% |
±6% |
Rated output current (note 5) |
11A |
4A |
1A |
1A |
10A |
3.5A |
1A |
1A |
8A |
2A |
2A |
1A |
Output current range |
2-12A |
0.5-5A |
0.2-1A |
0.2-1A |
2-12A |
0.5-5A |
0.2-1A |
0.2-1A |
2-12A |
0.2-5A |
0.2-2A |
0.2-1A |
Output power |
120W |
122.5W |
124W |
Ripple and the noise (note 2) |
80mV |
120mV |
80mV |
120mV |
80mV |
150mV |
80mV |
150mV |
80mV |
120mV |
180mV |
120mV |
Dc voltage adjustable scope |
CH1:-5%,+10% |
Start, rise, Keep time |
200ms, 50ms, 20ms Loaded with |
input |
Input voltage range |
88~132 VAC / 176~264 VAC 47-63Hz;The switch choice |
240~370VDC |
Exchange input current |
2.8A/115 V 1.6A/ 230 V |
efficiency |
77% |
76% |
80% |
Impulse current |
Cold start current 35 A |
Leakage current |
<3.5mA/240VAC |
Protection characteristics |
Overload protection |
105%~135% |
Protection way: cut output reset: restart |
Overvoltage protection |
CH1:115%~135% |
Protection way: cut output reset: restart |
environment |
Working temperature, humidity |
-10℃~+60℃;20%~90 %RH |
Keep temperature, humidity |
-20℃~+85℃;10%~95 %RH |
Vibrate resistance |
10~500Hz,2G 10min./1 cycle time, 60 minutes, the axis |
security |
Compression sex |
Input/output: 1.5 KVAC input and between to: |
1.5KVAC 输出与地:0.5KVAC |
Insulation resistance |
Between the input and output, the input and output, and ground: |
100M Ohms/500VDC |
Complies with the standards |
Safety standards |
Accord with |
1950,TUV EN60950 |
EMC Standard (note 4) |
Accord with |
EN55022(CISPR22),EN61000-3-2,-3,EN55024,EN61000-4-2,3,4,5,6,8,11; ENV50204 |
other |
weight |
0.86Kg |
packaging |
22pcs/19.2Kg/1.22CUFT |
note |
1. All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ℃ conditions measuring income value. |
2. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement. |
3. The output of maximum current total load, but not more than maximum output power. |
4. The power to consider as a device installed in final equipment, this equipment must be to make sure it’s EMC index. |
5. Specific output current see output drop forehead curve. |