Features:
High efficiency, high reliability and low cost
Switch input voltage range choice
100% full load and machine test
Protection characteristics: short circuit/overload
Air cooling
Working frequency 37 KHz
One year warranty
Size: 99 * 97 * 36 mm (L * W * H)
Technical parameter:
Mode |
S-25-5 |
S-25-12 |
S-25-15 |
S-25-24 |
OUTPUT |
Dc output voltage |
5V |
12V |
15V |
24V |
Output voltage tolerance |
±2% |
±1% |
±1% |
±1% |
Rated output current |
5A |
2.1A |
1.7A |
1.1A |
Output current range |
0-5A |
0-2.1A |
0-1.7A |
0-1.1A |
Output power |
25W |
25.2W |
25.5W |
26.4W |
Ripple and the noise |
50mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
Dc voltage adjustable scope |
+10,-5% |
±10% |
±10% |
±10% |
Start, rise, keep time |
800ms,50ms,10ms/115VAC 300ms,50ms,80ms/230VAC Loaded with |
INPUT |
Input voltage range |
85~264 VAC 47~ 63 Hz;120~370VDC |
Exchange input current |
0.6 A/115 V 0.35A/ 230 V |
efficiency |
72%/115VAC |
76%/115VAC |
77%/115VAC |
80%/115VAC |
Impulse current |
冷启动电流15A/115V 30A/230V |
Leakage current |
<0.75 mA/240VAC |
PROTECTION |
Overload protection |
110%~160% cut off output . Fold back current limiting, recovers automatically |
.... |
Overvoltage protection |
115%~135% |
Protection way: hiccups, auto recovery mode |
Environment |
Working temperature, humidity |
-10℃~+60℃;20%~90 %RH |
Keep temperature, humidity |
-20℃~+85℃;10%~95 %RH |
Vibrate resistance |
10 ~ 500 Hz ac, 2 G 10 min. / 1 cycle time, 60 minutes, the axis |
security |
Compression sex |
Between input and output |
:3KVAC Input and to |
:1.5KVAC Output and to |
:0.5KVAC |
Insulation resistance |
Between the input and output, the input and output, and ground: |
100M Ohms/500VDC |
Standard |
Safety standards |
Meet UL1012 |
, TUV EN60950 |
EMC standards (note 4) |
Accord with |
EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5;ENV50204,EN55024 |
Other |
Weight |
0.28Kg |
Packaging |
45pcs/13.2Kg/0.99CUFT |
Note |
1. All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ℃ conditions measuring income value. |
2. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement. |
3. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate. |
4. The power to consider as a device installed in final equipment, this equipment must be to make sure it’s EMC index. |
5. Specific output current see output drop forehead curve. |