Features:
High efficiency, high reliability and low cost
Switch input voltage range choice
100% full load and machine test
Protection characteristics: short circuit/overload
Air cooling
Working frequency 37 KHz
One year warranty
Size: 159*97*38mm(L*W*H)
Model |
S-50-5 |
S-50-12 |
S-50-15 |
S-50-24 |
S-50-48 |
OUTPUT |
DC Voltage |
5V |
12V |
15V |
24V |
48V |
Voltage Tolerance |
±2% |
±1% |
±1% |
±1% |
±1% |
Rated Current |
10A |
4.2A |
3.4A |
2.1A |
1A |
Current Range |
0-10A |
0-4.2A |
0-3.4A |
0-2.1A |
0-1A |
Rated Power |
50W |
50.4W |
51W |
50.4W |
48W |
Ripple & Noise |
75mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
DC Adjustment Range |
+10,-5% |
±10% |
±10% |
±10% |
±10% |
Setup, Rise, Hold Time |
200ms,100ms,20ms Loaded with |
INPUT |
Voltage Range |
85~132 VAC/170~264VAC 47~63 Hz;选择240~370VDC |
AC Curren |
1.3A/115 V 0.65A/ 230 V |
Efficiency |
71% |
78% |
78% |
82% |
84% |
Inrush Current |
Cold start current |
18A/115V 36A/230V |
Leakage Current |
<1 mA/240VAC |
PROTECTION |
Overload protection |
110%~160% |
Protection way: current limiting, automatic recovery |
ENVIRONMENT |
Working temperature, humidity |
-10℃~+60℃;20%~90 %RH |
Keep temperature, humidity |
-20℃~+85℃;10%~95 %RH |
Vibrate resistance |
10~500Hz,2G 10min./1 cycle time, 60 minutes, the axis |
SAFETY |
Compression sex |
Input/output: 1.5 KVAC input and between |
:1.5KVAC Output and to |
:0.5KVAC |
Insulation resistance |
Between the input and output, the input and output, and ground: |
100M Ohms/500VDC |
STANDARD |
Safety standards |
符合UL1012 |
EMC standards |
Design refer to FCC Part15 J Conduction Class B |
OTHERS |
weight |
0.51Kg |
packaging |
30pcs/15.8Kg/0.99CUFT |
NOTE |
All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ℃ conditions measuring income value. |
Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement. |
Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate. |
Specific output current see output drop forehead curve. |
|
Installation dimensions:
|