model |
S-150-5 |
S-150-9 |
S-150-12 |
S-150-13.5 |
S-150-15 |
S-150-24 |
S-150-27 |
S-150-48 |
output |
Dc output voltage |
5V |
9V |
12V |
13.5V |
15V |
24V |
27V |
48V |
Output voltage tolerance |
±2% |
±1% |
±1% |
±1% |
±1% |
±1% |
±1% |
±1% |
Rated output current |
30A |
16.7A |
12.5A |
11.2A |
10A |
6.5A |
5.6A |
3.2A |
Output current range |
0-30A |
0-16.7A |
0-12.5A |
0-11.2A |
0-10A |
0-6.5A |
0-5.6A |
0-3.2A |
Output power |
150W |
150.3W |
150W |
151.2W |
150W |
156W |
151.2W |
153.6W |
Ripple and the noise |
150mVp-p |
180mVp-p |
180mVp-p |
180mVp-p |
180mVp-p |
240mVp-p |
240mVp-p |
240mVp-p |
Dc voltage adjustable scope |
±10% |
-12%,+15% |
-12%,+10% |
-12%,+11% |
±10% |
-12%,+16% |
-12%,+11% |
±10% |
Start, rise, keep time |
100ms,50ms,20ms Loaded with |
input |
Input voltage range |
88~132 VAC/176~264VAC 47~63Hz,The switch choice |
248~370VDC |
Exchange input current |
3.2A/115 V 1.6A/ 230 V |
efficiency |
78% |
80% |
82% |
83% |
84% |
85% |
86% |
87% |
Impulse current |
Cold start current |
35A/230VAC |
Leakage current |
<3.5mA/240VAC |
protection characteristics |
Overload protection |
110%~160% |
Protection way: cut output, restart |
Overvoltage protection |
115%~135% |
Protection way: cut output, restart |
environment |
Working temperature, humidity |
-10℃~+60℃;20%~90 %RH |
Keep temperature, humidity |
-20℃~+85℃;10%~95 %RH |
Vibrate resistance |
10~500Hz,2G 10min./1 cycle time, 60 minutes, the axis |
security |
Compression sex |
Input/output: 1.5 KVAC input and between to KVAC output and the earth: 1.5:0.5 KVAC |
Insulation resistance |
Between the input and output, the input and output, and ground: |
100M Ohms/500VDC |
Accord with standard |
Safety standards |
Accord with |
UL1012, UL1950,TUV EN60950 |
EMC standard |
Accord with |
EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024 |
other |
weight |
0.8Kg |
packaging |
22pcs/18Kg/1.22CUFT |
note |
All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ℃ conditions measuring income value. |
Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement. |
Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate. |
The power to consider as a device installed in final equipment, this equipment must be to make sure it’s EMC index. |
Specific output current see output drop forehead curve. |