model |
S-201-12 |
S-201-13.5 |
S-201-15 |
S-201-24 |
S-201-27 |
S-201-48 |
output |
Dc output voltage |
12V |
13.5V |
15V |
24V |
27V |
48V |
Output voltage tolerance |
±1% |
±1% |
±1% |
±1% |
±1% |
±1% |
Rated output current |
16.5A |
14.7A |
13A |
8.3A |
7.4A |
4.2A |
Output current range |
0-16.5A |
0-14.7A |
0-13A |
0-8.3A |
0-7.4A |
0-4.2A |
Output power |
198W |
198.45W |
198W |
199.2W |
199.8W |
201.6W |
Ripple and the noise |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
200mVp-p |
240mVp-p |
Dc voltage adjustable scope |
-16%,+10% |
-12%,+11% |
-10%,+20% |
-16%,+10% |
-4%,+18% |
-15%,+17% |
Start, rise, keep time |
200ms,100ms,20ms Loaded with |
input |
Input voltage range |
90~132 VAC/180~264VAC 47~63 Hz;由开关选择254~370VDC |
Exchange input current |
4.5A/115VAC 2.5A/230VAC |
efficiency |
76% |
79% |
78% |
82% |
82% |
83% |
Impulse current |
50A/115V 50A/230V |
Leakage current |
<3.5 mA/240VAC |
Protection characteristics |
Overload protection |
115%~135% |
Protection way: current limiting, automatic recovery |
Overvoltage protection |
115%~135% |
Protection way: voltage limitation, automatic recovery |
High temperature protection |
RTH3 acuity 90 ℃, the temperature drop, cut off output automatically after recovery |
environment |
Working temperature, humidity |
-10℃~+50℃;20%~90 %RH |
Keep temperature, humidity |
-20℃~+85℃;10%~95 %RH |
Vibrate resistance |
10~500Hz,2G 10min./ 1 cycle time, 60 minutes, the axis |
security |
Compression sex |
Input/output: 1.5 KVAC input and between to KVAC output and the earth: 1.5:0.5 KVAC |
Insulation resistance |
Between the input and output, the input and output, and ground: |
100M Ohms/500VDC |
standard |
Safety standards |
符合UL1950 |
EMC standard |
Drsign refer to FCC Part15 J Conduction Class A |
other |
weight |
0.93Kg |
packaging |
12pcs/11.6Kg/0.93CUFT |
note |
All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ℃ conditions measuring income value. |
Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement. |
Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate. |
Specific output current see output drop forehead curve. |
|