Features:
High efficiency, high reliability
For AC power supply input global
100% full load and machine test
Protection characteristics: short circuit/overload/pressure
Built-in dc electric fan forced air cooling
Built-in fan switch control
Working frequency 110 KHz
PFC correction, built-in distance open/shutdown and voltage compensation signal interface
1 year warranty
Size: 170*120*93mm(L*W*H)
Technical parameter:
model |
SP-500 |
SP-500 |
SP-500 |
SP-500 |
SP-500 |
SP-500 |
-12 |
-13.5 |
-15 |
-24 |
-27 |
-48 |
output |
Dc output voltage |
12V |
13.5V |
15V |
24V |
27V |
48V |
Output voltage tolerance |
±1% |
±1% |
±1% |
±1% |
±1% |
±1% |
Rated output current |
40A |
36A |
32A |
20A |
18A |
10A |
Output current range |
0-40A |
0-36A |
0-32A |
0-20A |
0-18A |
0-10A |
Output power |
480W |
486W |
480W |
480W |
486W |
480W |
Ripple and the noise |
240mVp-p |
240mVp-p |
240mVp-p |
240mVp-p |
200mVp-p |
300mVp-p |
Dc voltage adjustable scope |
-16%,+10% |
-12%,+15% |
-10%,+20% |
-16%,+10% |
-12%,+11% |
-15%,+16% |
Start, rise, keep time |
1.5s,50ms,20ms Loaded with |
input |
Input voltage range |
88~264 VAC 47~63 Hz;124~370VDC |
Power factor |
PF>0.95/230VAC PF>0.95/115VAC Loaded with |
Exchange input current |
7A/115 V 3.5A/ 230 V |
efficiency |
81% |
82% |
83% |
85.50% |
86.50% |
87% |
Impulse current |
18A/115V 36A/230V |
Leakage current |
<3.5mA/240VAC |
Protection characteristics |
Overload protection |
105%~135% |
Protection way: current limiting, automatic recovery |
Overvoltage protection |
115%~135% |
Protection way: hiccups, auto recovery mode |
environment |
Working temperature, humidity |
-10℃~+50℃;20%~90 %RH |
Keep temperature, humidity |
-20℃~+85℃;10%~95 %RH |
Vibrate resistance |
10~500Hz,2G 10min./ 1 cycle time, 60 minutes, the axis |
security |
Compression sex |
3: KVAC between input and output and input and output KVAC: 1.5 to: |
0.5KVAC |
Insulation resistance |
Between the input and output, the input and output, and ground: |
100M Ohms/500VDC |
standards |
Insulation resistance |
Accord with |
UL1950,TUV EN60950 |
EMC standard |
Accord with |
EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204 |
other |
weight |
1.9Kg |
packaging |
10pcs/19.5kg/1.22CUFT |
note |
All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ℃ conditions measuring income value. |
Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement. |
Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate. |
The power to consider as a device installed in final equipment, this equipment must be to make sure it’s EMC index. |
Specific output current see output drop forehead curve. |
|
Installation dimensions:
|