Features:
High reliability, low ripple
Switch input voltage range choice
Protection characteristics: short circuit/overload/pressure/thermal
Built-in distance open/shutdown and voltage compensation signal interface
Has the parallel function
By external 2 ~ 5 V voltage control, which can adjust the output voltage of the rated voltage of the in the range of 40% ~ 100% in value
Built-in dc electric fan forced air cooling
One year warranty
Size : 291*132*68mm (L*W*H)
Technical parameter:
model |
SCN-800-12 |
SCN-800-15 |
SCN-800-24 |
SCN-800-48 |
output |
Dc output voltage |
12V |
15V |
24V |
48V |
Output voltage tolerance |
±1% |
±1% |
±1% |
±1% |
Rated output current |
66A |
54A |
33A |
16.6A |
Output current range |
0-66A |
0-54A |
0-33A |
0-16.6A |
Output power |
800W |
800W |
800W |
800W |
Ripple and the noise |
150mVp-p |
150mVp-p |
240mVp-p |
480mVp-p |
Dc voltage adjustable scope |
+ 5%; By external 2 ~ 5 V voltage control, which can adjust the output voltage of the rated voltage of the in the range of 40% ~ 100% in value |
Start, rise, keep time |
800ms, 50ms, 16ms Loaded with |
input |
Input voltage range |
90~130VAC / 180~260 VAC47~63 Hz;The switch choice |
260~370VDC |
Exchange input current |
13A/115 VAC 8.0A/ 230 VAC |
efficiency |
80% |
81% |
85% |
87% |
Impulse current |
60A/230V |
Leakage current |
3.5 mA/240VAC |
Protection characteristics |
Overload protection |
110%~135% |
Protection way: current limiting, delay shut off, restart |
Overvoltage protection |
110%~135% |
Protection way: cut output, restart |
High temperature protection |
TSW1 (power tube) temperature > 100 ℃, restart when cut off output |
environment |
Working temperature, humidity |
-10℃~+65℃,20%~90 %RH |
Keep temperature, humidity |
-20℃~+85℃,10%~95 %RH |
Vibrate resistance |
10~200Hz,2G 10min.. / 1 cycle time, 60 minutes, the axis |
security |
Compression sex |
I/P-O/P, I/P-FG:1500VAC |
Insulation resistance |
I/P-O/P, I/P-FG, >100M Ohms / 500VDC |
standards |
Safety standards |
Accord with |
UL1950,CSA22.2,IEC60950 |
EMC standard |
Accord with |
FCC Part 15 Class A |
other |
weight |
2.3Kg; |
packaging |
8pcs/24.0kg/CARTON |
note |
1. All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ℃ conditions measuring income value. |
|
2. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement. |
|
3. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate. |
|
4. The power to consider as a device installed in final equipment, this equipment must be to make sure it’s EMC index. |
Installation dimensions:
|