Features:
High efficiency, high reliability
For AC power supply input global
Protection characteristics: short circuit/overload/pressure
Air cooling
Has the boot display (light emitting diode (led)
Working frequency 50 KHz
1 year warranty
Size: 159 * 97 * 38 mm (L * W * H)
Technical parameter:
model |
T-60A |
T-60B |
T-60C |
CH1 |
CH2 |
CH3 |
CH1 |
CH2 |
CH3 |
CH1 |
CH2 |
CH3 |
output |
Dc output voltage |
5V |
12V |
-5V |
5V |
12V |
-12V |
5V |
15V |
-15V |
Output voltage tolerance |
±2% |
±6% |
±6% |
±2% |
±6% |
±6% |
±2% |
±6% |
±6% |
Rated output current |
5A |
2.5A |
0.5A |
5A |
2.5A |
0.5A |
5A |
2A |
0.5A |
Output current range |
0.5-7A |
0.2-3.5A |
0-1A |
0.5 -7A |
0.2-3.5A |
0-1A |
0.5-7A |
0.2-3A |
0-1A |
Output power |
57.5W |
61W |
62.5W |
Ripple and the noise |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
Dc voltage adjustable scope |
CH1:-5%,+10% |
Start, rise, keep time |
300ms,50ms,10ms/230VAC 800ms, 50ms, 10ms/115VAC Loaded with |
input |
Input voltage range |
85~264 VAC 47-63Hz;120~370VDC |
Exchange input current |
2A/115 V 1A/ 230 V |
efficiency |
69% |
72% |
72% |
Impulse current |
Cold start current |
30A/115V 60A/230V |
Leakage current |
<3.5mA/240VAC |
Protection characteristics |
Overload protection |
105%~150% |
Protection way: hiccups, auto recovery mode |
Overvoltage protection |
5V:115%~135% |
Protection way: reset: auto recovery hiccups mode |
environment |
Working temperature, humidity |
-10℃~+60℃;20%~90 %RH |
Keep temperature, humidity |
-20℃~+85℃;10%~95 %RH |
Vibrate resistance |
10~500Hz,2G 10min./ 1 cycle time, 60 minutes, the axis |
security |
Compression sex |
3: KVAC between input and output and input and output KVAC: 1.5 to: |
0.5KVAC |
Insulation resistance |
Between the input and output, the input and output, and ground: |
100M Ohms/500VDC |
Complies with the standards |
Safety standards |
Accord with |
UL1012,UL60950, TUV EN60950 |
EMC standard |
Accord with |
EN55022,EN61000-3-2,-3, EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024 |
other |
weight |
0.55Kg |
packaging |
30pcs/17Kg/0.99 CUFT |
note |
1. All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ℃ conditions measuring income value. |
2. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement. |
3. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate. |
4. The power to consider as a device installed in final equipment, this equipment must be to make sure it’s EMC index. |
5. Specific output current see output drop forehead curve. |
Installation dimensions:
|