T-120W
 
 

 Features:

The low price, high reliability

105 ℃ output capacitors

For AC power supply input global

Soft start current, effectively reduce the AC input impact

A short circuit protection and overload protection

Small volume, light weight

100% full load and machine test

EMI filters is installed inside, the ripple minimum

 
 
Technical parameter:
model T-100C T-100D
CH1 CH2 CH3 CH1 CH2 CH3
 Dc output voltage 5V 15V -15V 5V 12V 24V
 Output voltage tolerance ±2% ±6% ±6% ±2% ±6% ±6%
 Rated output current 10A 2.5A 1A 6A 2A 2A
 Output current range 2-12A 0.2-2.5A 0.1-1A 2-10A 0.1-2A 0.2-2A
 Ripple and the noise 80mVp-p 150mVp-p 150mVp-p 80mVp-p 150mVp-p 150mVp-p
 Into line stability ±0.5% ±1% ±1% ±0.5% ±1% ±1%
 Load stability ±1% ±5% ±5% ±1% ±5% ±5%
 Dc power output 100W 102W
 efficiency 77% 79%
 Dc voltage adjustable scope CH1;+10,-5% CH1;+10,-5%
 Input voltage range 85-132VAC/170-264VAC The switch choice
47-63Hz;240-370VDC
 Input current 2.5A/115V 1.25A/230V
 Impulse current 冷启动电流 30A/115V 60A/230V
 Leakage current <0.5mA/240VAC
 Overload protection 105%-150%M Type: current limiting reset: automatic recovery
 Overvoltage protection ............
 High temperature protection ............
 Temperature coefficient ±0.03%/℃(0-50℃) ON+5V
Start, rise, keep time 200ms,50ms,16ms
 Vibrate resistance 10-500Hz,2G 10min,/1 cycle time, 60 points, the axis
 Compression sex Input/output: 1.5 KvAC input and between shell: 1.5 KvAC output and the shell: 0.5 KvAC
 Isolating resistor Between the input and output, the input and output and the shell: shell,
:500VDC/100MΩ
Working temperature, humidity -10℃-+60℃(Reference output characteristics graph
),20%-90%RH
Storage temperature, humidity -20℃-+85℃,10%-95RH
 Shape dimension 199×110×50mm
 weight 0.83kgs
 Safety standards Meet the UL1012 requirements (not applied for mark)
 EMC mark Meet the FCC part 15 J condition grade B
 comments 1. The above parameters test conditions for: 230 VAC, rated load, 25 ℃ and 70% Rh temperature.
2. Tolerance: include setting tolerance, the line stability, load stability (note 5).
3. Corrugated test: 20 MHz A12 "with" twisted-pair with 0.1, interrupt them through programs and 47 uF capacitance breaker.
4. Into line voltage stability test: full load into line voltage to the lowest highest voltage.
5. Load stability test: the load from 0% to 100%.
 
 
Installation dimensions: