Low price and high reliability105℃ output capacitorAC input power suitable for the worldHight efficiency and low operation temperatureSoft-start current can reduce the AC input impact effecticlyWith Short-circuit and owwerload protectionCompact size,light weight100% full-load burning testInstalled with EMI filter,minimum wave.

Product Description:

Model / Specification

DR-240-24

DR-240-48

DC output voltage

24V

48V

Output voltage error (Note2)

±1%

±1%

Rated output current

10A

5A

Output current rage

0-10A

0-5A

Wave and noise(Note3)

80mVp-p

150mVp-p

Inlet stability(Note4)

±0.5%

±0.5%

Load stability(Note5)

±1%

±1%

DC output power

240W

240W

Efficiency

84%

85%

Adjustable range for DC voltage

21.6-26.4V

43.2-52.8V

AC input voltage range

88~264VAC 47~63HZ;120~370VDC

Input current

3.5A/115V 1.8A/230V

AC impulse current

Cold-start current 30A/115V 50A/230V

Leakage current

<3.5mA/240VAC

Overload protection

105%~150% Type:PULSING HICCUP SHUTDOWN Reset: auto recovery

Over-voltage protection

30-34V

54-60V

High-temperature protection

100℃±5℃(TSW1)

Temperature coefficient

±0.03%℃(0~50℃)

Setup rise hold up time

800ms,40ms,20ms/230VAC 800ms,40ms,20ms/115VAC

Vibration

10~500Hz,2G 10min./1cycle,Period for 60min,Each axes

Withstand voltage

Input and output interval:3KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC

Isolation resistance

Input and output interval,Input and enclosure,Output and enclosure:500VAC/100M Ohms

Working temperature and humidity

-10℃~+50℃,20%~90%RH

Store temperature and humidity

-20℃~+85℃,10%~95RH

Overall dimension

125.2*125.2*100mm

Weight

1.2Kgs 20PCS/14.4KG/1.2CUFT

Safety standards

Meet UL1012

EMC standards

Meet Part 15J conduction class B

Note:1.The testing condition for the parameter above is:230VAC input, rated load,25℃ 70%Rh,Humidity
2.Error,include the setting error, line stability and load stability.(Note:5)
3.Wave test:adopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting
4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.
5.Load stability test: The load is from 0% to 100%,others 60%.
6.C2、3、11must be knocked down.

 
SendMessage