Low price and high reliability105℃ output capacitorAC input power suitable for the worldHight efficiency and low operation temperatureSoft-start current can reduce the AC input impact effecticlyWith Short-circuit and owwerload protectionCompact size,light weight100% full-load burning testInstalled with EMI filter,minimum wave.

Product Description:

Model /Specification

S-10-5

S-10-12

S-10-24

DC output voltage

5V

12V

24V

Output voltage error (Note2)

±2%

±1%

±1%

Rated output current

2A

0.8A

0.4A

Output current rage

0-2A

0-0.8A

0-0.4A

Wave and noise(Note3)

50mVp-p

50mVp-p

100mVp-p

Inlet stability(Note4)

±0.5%

±0.5%

±0.5%

Load stability(Note5)

±1%

±0.5%

±0.5%

DC output power

10W

10W

10W

Efficiency

65%

68%

72%

Adjustable range for DC voltage

±10%

±10%

±10%

AC input voltage range

85~264VAC 47~63Hz

Input current

0.5A/115V 0.25A/230V

AC impulse current

Cold-start current 15A/115V 30A/230V

Leakage current

<0.5mA/240VAC

Overload protection

105%~150%Type: current limiting ;Reset: auto recovery

Over-voltage protection

……

High-temperature protection

……

Temperature coefficient

±0.02%℃(0~50℃)

Setup rise hold up time

200ms,100ms,30ms

Vibration

10~500Hz,2G 10min./1cycle,Period for 60min,Each axes

Withstand voltage

Input and output interval:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC

Isolation resistance

Input and output interval,Input and enclosure,Output and enclosure:0500VAC/100M Ohms

Working temperature and humidity

-10℃~+50℃,20%~90%RH

Store temperature and humidity

-20℃~+85℃,10%~95RH

Overall dimension

69 x 75 x 28mm

Weight

0.12Kgs

Safety standards

Meet UL1012

EMC standards

……

Note:1.The testing condition for the parameter above is:230VAC input, rated load,25℃ 70%Rh,Humidity
2.Error,include the setting error, line stability and load stability.(Note:5)
3.Wave test:adopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting
4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.
5.Load stability test:The load is from 0% to 100%,others 60%.
6.C2、3、11must be knocked down.

 