Low price and high reliability  105 output capacitor AC  Input power suitable for the world  Hight efficiency and low operation temperature  Soft-start current can reduce the AC input impact effectively   With Short-circuit and overload protection Compact size, light weight  100% full-load burning test  Installed with EMI filter, minimum wave.

Product Description:

Model / Specification

S-250-12

S-250-13.5

S-250-15

S-250-24

S-250-27

S-250-48

DC output voltage

12V

13.5V

15V

24V

27V

48V

Output voltage error (Note2)

±1%

±1%

±1%

±1%

±1%

±1%

Rated output current

20A

18A

17A

10A

9A

5A

Output current rage

0-20A

0-18A

0-17A

0-10A

0-9A

0-5A

Wave and noise(Note3)

150mVp-p

150mVp-p

150mVp-p

150mVp-p

150mVp-p

150mVp-p

Inlet stability(Note4)

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Load stability(Note5)

±1%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

DC output power

300W

297W

300W

300W

297W

312W

Efficiency

82%

83%

84%

86%

86%

87%

Adjustable range for DC voltage

10-13.2V

12-15V

13.5-18V

20-26.4V

24-30V

41-56V

AC input voltage range

88132VAC/176264VAC BY SWITCH 4763Hz;124370VDC

AC impulse current

6A/115V 3.5A/230V

Power factor

0.95/100240VAC

Impact current

20A/115V 40A/230V

Leakage current

<3.5mA/240VAC

Overload protection

105%135% TypeFOLDBACK Cut off output Reset: auto recovery

Over-voltage protection

13.816.2V

15.518.2V

1821V

27.632.4V

3136.5V

57.667.2V

Fan controlO.T.P.

RTH1 OR RTH2>=50 FAN ON,<=45 FAN OFF,>=70 Cut off output

Temperature coefficient

±0.03%(050)

Setup rise hold up time

1.5s,50ms,20ms

Vibration

10500Hz,2G 10/1cyclePeriod for 60min,EACH AXES

Withstand voltage

Input and output interval3KVAC, Input and enclosure1.5KVAC Output and enclosure0.5KVAC

Isolation resistance

Input and output intervalInput and enclosureOutput and enclosure500VDC/100M Ohms

Working temperature and humidity

-10+50,20%90%RH

Store temperature and humidity

-20+85,10%95%%RH

Overall dimension

215*115*50mm

Weight

1.15Kgs

Safety standards

UL1950,TUV EN60950

EMC standards

IEC1000-42,3,4,5,6,8,11 IEC100-3-2

Note:

1. The testing condition for the parameter above is: 230VAC input, rated load, 25 70%Rh, Humidity
2. Error, include the setting error, line stability and load stability. (Note:5)
3. Wave test: adopting“A12”double wire for 20MHz, and 0.1uF&uF capacitor short-circuit for interrupting
4. Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.
5. Load stability test: The load is from 0% to 100%, others 60%.
6. C2
311must be knocked down.

 

 

 

 

 

Other products from this company »