Catalog

 

Search

Enter your keyword

 

 

Contact Us

S-40

Add to Inquiry Basket
View Inquiry Basket
print this page Print This Page
bookmark this page Bookmark This Page
tell a friend
live messenger cnjyins01@hotmail.com cnjyins02@hotmail.com cnjyins03@hotmail.com cnjyins@hotmail.com
skype me cnjyins01 cnjyins02 cnjyins03 cnjyins04
e-mail us jyins@jyins.com
Send Inquiry Send Inquiry
catalogue download Catalogue Download

Low price and high reliability105℃ output capacitorAC input power suitable for the worldHight efficiency and low operation temperatureSoft-start current can reduce the AC input impact effecticlyWith Short-circuit and owwerload protectionCompact size,light weight100% full-load burning testInstalled with EMI filter,minimum wave.

Product Description:

Model /Specification

S-40-5

S-40-12

S-40-15

S-40-24

DC output voltage

5V

12V

15V

24V

Output voltage error(Note2)

±2%

±1%

±1%

±1%

Rated output current

8A

3.5A

2.8A

1.8A

Output current rage

0-8A

0-3.5A

0-2.8A

0-1.8A

Wave and noise(Note3)

75mVp-p

100mVp-p

100mVp-p

100mVp-p

Inlet stability(Note4)

±0.5%

±0.5%

±0.5%

±0.5%

Load stability(Note5)

±1%

±0.5%

±0.5%

±0.5%

DC output power

40W

42W

42W

43W

Efficiency

72%

76%

77%

78%

Adjustable range for DC voltage

±10,-5%

±10%

±10%

±10%

AC input voltage range

85~132VAC/170~264VACselected by switch 47~63Hz;240~370VDC

Input current

1.2A/115V 0.6A/230V

AC impulse current

Cold-start current 18A/115V 36A/230V

Leakage current

<1mA/240VAC

Overload protection

105%~150% Type: current limiting;  Reset; auto recovery

Over-voltage protection

115%~135%

High-temperature protection

……

Temperature coefficient

±0.03%℃(0~50℃)

Setup rise hold up time

800ms,50ms,15ms/115V 300ms,50ms,60ms/230VAC

Vibration

10~500Hz,2G 10min./1cycle,Period for 60min,Each axes

Withstand voltage

Input and output interval:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC

Isolation resistance

Input and output interval,Input and enclosure,Output and enclosure:0500VAC/100M Ohms

Working temperature and humidity

-10℃~+60℃,20%~90%RH

Store temperature and humidity

-20℃~+85℃,10%~95RH

Overall dimension

129*98*38mm

Weight

0.45Kgs

Safety standards

MeetUL1012

EMC standards

……

Note:
1.The testing condition for the parameter above is:230VAC input, rated load,25℃ 70%Rh,Humidity
2.Error,include the setting error, line stability and load stability.(Note:5)
3.Wave test:adopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting
4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.
5.Load stability test: The load is from 0% to 100%,others 60%.
6.C2、3、11must be knocked down.

 

Other products from this company »

SendMessage