Catalog

 

Search

Enter your keyword

 

 

Contact Us

T-50 Series switching power supply

Add to Inquiry Basket
View Inquiry Basket
print this page Print This Page
bookmark this page Bookmark This Page
tell a friend
live messenger cnjyins01@hotmail.com cnjyins02@hotmail.com cnjyins03@hotmail.com cnjyins@hotmail.com
skype me cnjyins01 cnjyins02 cnjyins03 cnjyins04
e-mail us jyins@jyins.com
Send Inquiry Send Inquiry
catalogue download Catalogue Download

Low price and high reliability105℃ output capacitorAC input power suitable for the worldHight efficiency and low operation temperatureSoft-start current can reduce the AC input impact effecticlyWith Short-circuit and owwerload protectionCompact size,light weight100% full-load burning testInstalled with EMI filter,minimum wave.

Product Description:

Model /Specification

T-50A

T-50B

T-50C

T-50D

CH1

CH2

CH3

CH1

CH2

CH3

CH1

CH2

CH3

CH1

CH2

CH3

DC output voltage

5V

12V

-5V

5V

12V

-12V

5V

15V

-15V

5V

15V

24V

Output voltage error (Note2)

±2%

±5%

±5%

±2%

±5%

±5%

±2%

±5%

±5%

±2%

±6%

±6%

Rated output current

7A

1A

1A

5A

1A

1A

4A

1A

1A

3A

1A

1A

Output current rage

0.6-7A

0.2-1A

0.2-1A

0.6-5A

0.2-1A

0.2-1A

0.6-4A

0.2-1A

0.2-1A

0.6-4A

0.2-2A

0.2-1A

Wave and noise(Note3)

100mV

100mV

100mV

100mV

100mV

100mV

100mV

100mV

100mV

50mV

120mV

120mV

Inlet stability(Note4)

±0.5%

±0.5%

±0.5

±0.5%

±0.5%

±0.5

±0.5%

±0.5%

±0.5

±0.5%

±1%

±1%

Load stability(Note5)

±1%

±4%

±4%

±1%

±4%

±4%

±1%

±4%

±4%

±1%

±5

±5%

DC output power

52W

49W

50W

51W

Efficiency

66%

69%

71%

72%

Adjustable range for DC voltage

CH1+10,-5%

CH1+10,-5%

CH1+10,-5%

CH1+10,-5%

AC input voltage range

85~132VAC/170~264VAC selected by switch 47~63Hz;240~370VDC

Input current

1.6A/115V 0.8A/230V

AC impulse current

Cold-start current 20A/115V 40A/230V

Leakage current

<0.5A/240VAC

Overload protection

105%~150% Type:PULSING HICCUP SHUTDOWN Reset auto recovery

Over-voltage protection

……

High-temperature protection

 

Temperature coefficient

±0.03%℃(0~50℃) ON+5V OUTPUT

Setup rise hold up time

200ms,50ms,16ms

Vibration

10~500Hz,2G 3AXES 10min./1cycle,Period for 60min,Each axes

Withstand voltage

Input and output interval:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC

Isolation resistance

Input and output interval,Input and enclosure,Output and enclosure:500VAC/100M Ohms

Working temperature and humidity

-10℃~+60℃,20%~90%RH

Store temperature and humidity

-20℃~+85℃,10%~95%RH

Overall dimension

159*97*38mm

Weight

0.54Kgs

Safety standards

Meet UL1012 requirement(Not apply for the mark)

EMC standards

……

Note:1.The testing condition for the parameter above is:230VAC input, rated load,25℃ 70%Rh,Humidity
2.Error,include the setting error, line stability and load stability.(Note:5)
3.Wave test:adopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting
4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.
5.Load stability test: The load is from 0% to 100%,others 60%.
6.C2、3、11must be knocked down.

 
SendMessage