■ Connection: 30cm wire
■ L, N: AC Input
■-V: DC output negative terminal
■ + V: DC output positive terminal

AC input voltage range

170-264VAC

Input current

1A/230V

AC inrush current

Cold-start current 36A/230V

Leakage current

<1mA/240VAC

Over load protection

105-150% hiccup mode,auto-recovery

Water level

IP68

Setup rise lold up time

200ms 100ms 20ms

Withstand voltage

I/P-O/P:1.5KVAC 1minute
I/P-FG:1.5KVAC 1minute
O/P-FG:0.5KVAC 1minute

Working temperature

0-40℃@100%put
-10-40℃@80%put
50℃@60%put

Weight/packing

 

 

type

Output

Error

Range

Efficiency

LPV-60-12

12V,0-5A

±1%

120mV

76%

LPV-60-15

15V,0-2.5A

±1%

150mV

77%

LPV-60-24

24V,0-1.7A

±1%

150mV

79%

LPV-60-48

48V,0-1.2A

±1%

150mV

81%

NOTE:

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pairwire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

5. If the power supply is short-circuited under no load, it will recover automatically when short-circuit is removed.

 

Other products from this company »