Language Options:
EnglishCatalog
Search
Enter your keyword
![]()
Contact Us
|
|
||||||||||||||||||||||||
■ Connection: 30cm wire
■ L, N: AC Input
■-V: DC output negative terminal
■ + V: DC output positive terminal
|
AC input voltage range |
170-264VAC 47-63HZ |
|
Input current |
1.6A/230V |
|
AC inrush current |
Cold-start current 60A/230V |
|
Leakage current |
<3.5mA/240VAC |
|
Over load protection |
105-150% hiccup mode,auto-recovery |
|
Water level |
IP68 |
|
Setup rise lold up time |
100ms 50ms 20ms |
|
Withstand voltage |
I/P-O/P:1.5KVAC 1minute |
|
Working temperature |
0-40℃@100%put |
|
Weight/packing |
|
|
type |
Output |
Error |
Range |
Efficiency |
|
LPV-150-24 |
24V,0-6.3A |
±1% |
240mV |
85% |
|
LPV-150-36 |
27V,0-4.2A |
±1% |
240mV |
86% |
|
LPV-150-48 |
48V,0-3.2A |
±1% |
240mV |
87% |
|
NOTE: 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. If the power supply is short-circuited under no load, it will recover automatically when short-circuit is removed. |
||||